ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

Item-1_MM_11031324

2HR 1425RPM,1PH,50HZ,182TC,X3646L,XPFC

Ship Weight

121.000 LB

UPC

781568120514

A Product has been discontinued

SPECS

DRAWINGS

NAMEPLATE

PERFORMANCE

PARTS

Catalog Number

Enclosure

Frame

Frame Material

Frequency

Motor Letter Type

Output @ Frequency

Phase

Synchronous Speed @

Frequency

Voltage @ Frequency

XP Class and Group

XP Division

Agency Approvals

CL5027T-50

XPFC

182TC

Steel

50.00 Hz

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

Cap Start, Induction

Run

2.000 HP@50HZ

1

1500RPM@50 HZ

110.0V@50 HZ

220.0V@50 HZ

CLGPD

Division l

UL

CSA

Lifting Lugs

Locked Bearing Indicator

Motor Lead Exit

Motor Lead Termination

Motor Lead

Quantity/Wire Size

Motor Type

Mounting Arrangement

Number of Poles

Overall Length

Power Factor

Product Family

Pulley End Bearing Type

Pulley Face Code

Pulley Shaft Indicator

Rodent Screen

No Lifting Lugs

Locked Bearing

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

Ko Box

Flying Leads

4@14AWG,APH

3646L

4

20.36 IN

78

General Purpose

Ball

C-Face

Standard

None

Ambient Temperature

40℃

Auxillary Box

No Auxilary Box

Auxillary Box Lead

None

Termination

Base Indicator

Rigid

Bearing Grease Type

Polyrex EM(-20F

+300F)

Blower

None

Current @ Voltage

This email address is being protected from spambots. You need JavaScript enabled to view it.

This email address is being protected from spambots. You need JavaScript enabled to view it.

Design Code

L

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

Drip Cover

No Drip Cover

Duty Rating

CONT

Efficiency @ 100% Load

77.0%

Electrically Isolated Bearing

Not Electrically

Isolated

Feedback Device

NO FEEDBACK

High Voltage Full Load

11.5 a

Amps

Front Face Code

Standard

Front Shaft Indicator

None

Heater Indicator

No Heater

Insulation Class

B

Inverter Code

Not Inverter

KVACode

K

RoHS Status

ROHS COMPLIANT

Service Factor

1.00

Shaft Diameter

1.125 IN

Shaft Extension Location

Pulley End

Shaft Ground Indicator

No Shaft Grounding

Shaft Rotation

Reversible

Shaft Slinger indicator

No Slinger

Speed

1425rpm

Speed Code

single speed

Motor Standards

NEMA

Starting Method

Direct on line

Thermal Device-Bearing

NONE(OLD)

Thermal Device-

Normally closed

Winding

Thermostat

Vibration Sensor

No Vibration Sensor

Indicator

Winding Thermal 1

None

Winding Thermal 2

None

XP Temp Code

T2C

MOTOR PILOT/HUB – C3 - ???

INPUT SPLINE – 14 - 14T 12/24

RATIO OPTIONS – 42 - 42.42:1

OUTPUT SPINDLE – F7 - ???

SPECIAL FEATURES – Z - Boot Seal

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

A2, B2, C2
DIM."A"。
Soe Spindie Outout -
Options P.18
12.375(314.33)
13.80(350.5
11.25(285.日)
10.905
7.00
Options P.18
spindle
Output
See
(334.95)
(393.7)
279.4)
15.00
13.187
00
A1,A2:12.42(315.5)+ Dim"A"
B1,B2:11.10(281.9)+Dim "A"
C1,C2:12.33 (313.2)+Dim"A"
D1:13.06(331.7)+Dim"A"
3.74(95.0)-
一.76 (19.3)
2.26(57.4)PREFERRED
-CENTER OF LOAD
A1,A2: 300(7.62)-
B1,B2: 395(10.03)
C1,C2:,520(13.21)
1063(270.00)
口仁
Dimensions given in: INCHES (mm)
-A2,B2,C2-8+oies,Equalty Spaced-
-676--681(17-22-17.30)Dia ThruHeles-
OIL FILL OR
DRAIN PLUG
INPUT
SPLINE
See
Feature
Char
MOUNTING
CHARRT
SEE
Dim"A"
See Spindie Ouput
Options P.18
2.29.
(58.2)
A1,B1,C1,D1
314"-16 UNF-8 holes @ 9.50"dia
"O"RING
REQUIRED
.96
"O" Ring Sizes:

ELECTRIC MOTOR ABB Electrical resistance of the insulation, МOhm × km: 10.

(24.4)
SAE A2-042,
MAX. SHAFT LENGTH
SAE B 2-155,
2.298(58.37)-14T
SAEC 2-159
(Not supplied by Auburn Gear)
1.01(25.7) PREFERRED
CENTER OF LOAD
MOTOR TOBE MOUNTED
WITH OIL SEALING BOLTS
OIL FILL OR
DRAIN PLUG
Ouput
Rotation
is Same As
Input Rotation
A1, B1,C1, D1:10 Holes, Equally Spaced
.847 -.850 (21.51 — 21.59) Dia. Thru Holes

9

PUMP RZ-30 (SH 40-4-19,5/4 with a frame and an electric motor

Pump capacity, kW:         5.5     

Rotation speed, r.p.m.:    1,000

Temperature of the transported medium, °С:   0-80

Pump efficiency, %, not less than: 60

Admissible NPSH, m, not more than: 15

Pump purpose: to pump lubricants

Outlet pressure - 4atm

Q (delivery), m3/h: 19.5

motor type: AOLS2-22-4;

electric motor power, kW:  5.5;

voltage, V:  ̴ 380;

insulation class: F;

Main dimensions  (interaxial longitudinal and transverse distances along the centers of the pump supporting "legs", the height from the bearing area to the shaft axis, and the dimensions along the areas of the suction and delivery nozzle ends)  need to be clarified and agreed on with the client.

2

 

The Sub-contractor’s warranty obligations mean the quality guarantees of pumps, and guarantees of their operation quality during the warranty period, as well as the obligations to remove, at its own expense, the article defects revealed during the warranty period or to replace the respective equipment unless it proves that the defects have occurred as a result of violation by the Client of article operation or storage rules. The warranty obligations should be fulfilled by the subcontractor

provided that the Recipient meets the requirements of the manufacturer’s instruction on operations.

The warranty obligations are specified in the pump operation instruction, or in any other document which is a part of the operational documentation of the bidder.

 

 

Warranty – at least 2 years.

These specifications provide “minimum” requirements. Participants are also encouraged to quote items that have substantially equivalent or better characteristics.

Availability of service centre in Ukraine is mandatory.

           

 

 

 

 

 

 

 

 

LOT 2      ElECTRIC DISTRIBUTION CABLES

 

PLACE OF DELIVERY: DAP KYIV

Object: Electric distribution cables  - 20320 m var. types

 

Specification in the table below:

 

 

#

 

 

Type

 

 

Technical data

 

Quan-tity, m

 

1

Cable KVVGng 4Х1,5  

1. Number of cores, pcs.: 4.

2. Cross-section of the core, mm²: 1.5.

3. Electrical resistance of the core, Ohm / km: 12.1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic .

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 9.3.

8. Bulk weight, kg/m: 0.129.

9. Thickness of insulation, mm: 0.6.

10.Thickness of the cable sheath, mm: 1.5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature  +35°С, %, not more than: 98.

13. Admissible continuous temperature of the core heating, °С, not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility.

3430

2

Cable KVVGng 5х1,5  

1. Number of cores, pcs.: 5.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 10.

8. Bulk weight, kg/m: 0,153.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

705

3

Cable KVVGng 7х1,5  

1. Number of cores, pcs.: 7.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 10,8.

8. Bulk weight, kg/m: 0,196.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

910

4

Cable KVVGng 10х1,5  

1. Number of cores, pcs.: 10.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 13,4.

8. Bulk weight, kg/m: 0,271.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

2140

5

Cable KVVGng 14х1,5  

1. Number of cores, pcs.: 14.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 14,4.

8. Bulk weight, kg/m: 0,354.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

740

6

Cable KVVGng 19х1,5  

1. Number of cores, pcs.: 19.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 16.

8. Bulk weight, kg/m: 0,460.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

90

7

Cable KVVGng 27х1,5

1. Number of cores, pcs.: 27.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 19,4.

8. Bulk weight, kg/m: 0,652.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

965

8

Cable KVVGng 14х2,5  

1. Number of cores, pcs.: 14

2. Cross-section of the core, mm²: 2,5

3. Electrical resistance of the core, Ohm / km: 18,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23

7. External diameter of the cablle, mm: 16,5.

8. Bulk weight, kg/m: 0,0,441.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

90

9

Cable KVVGEng 4Х1,5

1. Number of cores, pcs.: 4.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 10.

8. Bulk weight, kg/m: 0,2.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

15. Availability of the screen: aluminium foil.

7950

10

Cable KVVGEng 5х1,5

1. Number of cores, pcs.: 5.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 11.

8. Bulk weight, kg/m: 0,22.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

15. Availability of the screen: aluminium foil.

1965

11

Cable KVVGEng 10х1,5

1. Number of cores, pcs.: 10.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 14.

8. Bulk weight, kg/m: 0,36.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

15. Availability of the screen: aluminium foil.

1035

12

Cable KVVGEng 14х1,5

1. Number of cores, pcs.: 14.

2. Cross-section of the core, mm²: 1,5.

3. Electrical resistance of the core, Ohm / km: 12,1.

4. Electrical resistance of the insulation, МOhm × km: 10.

5. Core: copper round monolithic.

6. Rated current per core, А: 23.

7. External diameter of the cablle, mm: 15.

8. Bulk weight, kg/m: 0,44.

9. Thickness of insulation, mm: 0,6.

10. Thickness of the cable sheath, mm: 1,5.

11. Environment temperature, °С: from - 50 to +50.

12. Relative humidity of the air at the temperature +35°С, %,not more than: 98.

13. Admissible continuous temperature of the core heating, °С,not more than: 70.

14. Sheath from the PVC plasticate with the reduced combustibility

15. Availability of the screen: aluminium foil.

300

 

Manufacturing warranty and  Service life must comply with the passport data of the manufacturer. In any case, the warranty cannot be less than 2 years.

 

 

 

 

 

 

 Geared Motors And Electric Motor Manufacturer

The best service from our transmission drive expert to your inbox directly.

Get in Touch

Yantai Bonway Manufacturer Co.ltd

ANo.160 Changjiang Road, Yantai, Shandong, China(264006)

T+86 535 6330966

W+86 185 63806647

© 2024 Sogears. All Rights Reserved.